Modelo: UT33 Series Power Frequency Online UPS
Marca: Potencia unitaria
Período De Garantía: 3 meses-1 año, otro, 3 años
Lugar De Origen: porcelana
Fase: Tres fases
Proteccion: Relámpago, Cortocircuito, Sobretensión, Sobrecorriente, Cargas desequilibradas
Peso: otro
Tipos De: En línea
Ámbito De Aplicación: ORDENADOR, Seguridad / Monitoreo / Alarma, Militar, MÉDICO, INSTRUMENTACIÓN, Redes, Telecomunicaciones
Capacity: 10KVA/15KVA/20KVA/30KVA/40KVA/60KVA/80KVA/100KVA/120KVA /160KVA/200KVA/250KVA/300KVA/400KVA/500KVA/600KVA/800KVA
Unidades de venta | : | Piece/Pieces |
Tipo de paquete | : | Embalaje de cartón |
Ejemplo de una imagen | : | |
Descargar | : |
UT33 series 10KVA/10KW, 15KVA/15KW, 20KVA/20KW, 30KVA/30KW, 40KVA/40KW, 60KVA/60KW, 80KVA/80KW, 100KVA/100KW, 120KVA/120KW,160KVA/160KW,200KVA/200KW,250KVA/250KW, 300kva/300kW, 400kva/400kW, 500kva/500kW, 600kva/600kW, 800kVA/800kW UPS es un UPS basado en transformadores, que se usa comúnmente en la fuente de alimentación industrial. Esta serie Industrial UPS es un UPS de baja frecuencia con tecnología de tejedor flexible y una función inteligente de gestión de baterías. Su función de protección está completa y está equipada con alarma de sonido y luz. A menudo se usa en centros de datos, salas de red, equipos de precisión inteligentes, finanzas, telecomunicaciones, seguros, transporte, impuestos, militares, seguridad, energía, educación, gobierno, fabricación y otras industrias.
◆ Aplicación
D ATA Center, la sala de computadoras de la red, equipos de precisión inteligente , financiero, telecomunicaciones, seguros, transporte, impuestos, militares, seguridad, energía, educación, gobierno, fabricación y otras industrias , etc.
◆ Características
● Interruptor estático de alto confiable
● Autognóstico y autoproteo
● Gestión inteligente de batería recargable
● Diálogo Hu Man-Machine con la monitorización remota y la gestión de la red
● Interfaz de pantalla en inglés fuerte
● La doble transformación es un diseño en línea
● Tecnología de tejedor flexible
● Sistema con alta eficiencia
● O UT Transformer
● Con rectificador opcional de 12 pulsos
● Permitir al 100% equilibrar el trabajo
● Función inteligente de gestión de baterías
● Para proteger la función está lista
● alarma de sonido y luz
● Una variedad de salida de voltaje
● Color opcional
Model |
UT33010 |
UT33015 |
UT33020 |
UT33030 |
UT33040 |
UT33060 |
UT33080 |
UT33100 |
UT33120 |
|
Capacity |
10kVA |
15kVA |
20kVA |
30kVA |
40kVA |
60kVA |
80kVA |
100kVA |
120kVA |
|
Input |
Phase |
3-phase+N+G |
||||||||
Rated Voltage |
440/460/480Vac |
|||||||||
Input Voltage Range |
285-528Vac |
|||||||||
Rated Frequency |
50/60Hz |
|||||||||
Input Frequency Range |
50H±10%, 60Hz±10% |
|||||||||
THDi |
<10% |
|||||||||
Soft Start |
1-100%, 5 seconds |
|||||||||
Bypass |
Phase |
3-phase+N+G |
||||||||
Voltage Range |
440/460/480Vac ±10% |
|||||||||
Frequency Range |
50/60H±10% |
|||||||||
Output |
Rated Voltage |
440/460/480Vac |
||||||||
Voltage Regulation |
±1% for balance load; ±3% for unbalance load |
|||||||||
Rated Frequency |
50/60Hz |
|||||||||
Frequency Precision |
50/60Hz±0.05%(Battery mode) |
|||||||||
Outout PF |
0.9 |
|||||||||
THDu |
<2% (linear load); <4% (non-linear load) |
|||||||||
Crest Factor |
3:1 |
|||||||||
Dynamic Voltage Transient |
<5% (from 0 to 100% load) |
|||||||||
Transient Recovery Time |
<10ms (±5%) |
|||||||||
Inverter Overload |
125% load for 10 mins; 150% load for 1min |
|||||||||
Battery |
Voltage |
360Vdc |
||||||||
Battery Type |
Sealed maintenance-free lead-acid battery |
|||||||||
Charging Voltage |
Float charging: 405Vdc; boost charging: 435Vdc |
|||||||||
Charging Current |
1-50A, settable according the battery capacity |
|||||||||
System |
Efficiency |
91% |
||||||||
Protection Function |
Output short circuit protection; current-limiting protection |
|||||||||
Transfer Time |
Normal mode to battery mode, 0ms |
|||||||||
Display |
LCD+LED+Keyboard |
|||||||||
IP Class |
IP20 |
|||||||||
Communication Interface |
RS232, RS485(optional), SNMP card (optional) |
|||||||||
Temperature |
Operation: 0-40 ℃; storage: -25-55 ℃ |
|||||||||
Relative Humidity |
0-95%, no-condensing |
|||||||||
Altitude |
<1500. Within 1500 to 4000m, power capacity decreases by 1% per 100m increasing in altitude |
|||||||||
Noise (1-meter away) |
<65dB |
|||||||||
Physical |
Weight (kg) |
200 |
250 |
340 |
400 |
480 |
650 |
900 |
1200 |
1300 |
Dimension (W*D*H)mm |
725*450*1135 |
855*450*1235 |
715*855*1500 |
1100*900*1700 |
Model |
UT33160 |
UT33200 |
UT33250 |
UT33300 |
UT33400 |
UT33500 |
UT33600 |
UT33800 |
|
Capacity |
160kVA |
200kVA |
250kVA |
300kVA |
400kVA |
500kVA |
600kVA |
800kVA |
|
Input |
Phase |
3-phase+N+G |
3-phase+G |
||||||
Rated Voltage |
440/460/480Vac |
||||||||
Input Voltage Range |
285-528Vac |
||||||||
Rated Frequency |
50/60Hz |
||||||||
Input Frequency Range |
50H±10%, 60Hz±10% |
||||||||
THDi |
<10% |
||||||||
Soft Start |
1-100%, 5 seconds |
5-600 seconds, settable |
|||||||
Bypass |
Phase |
3-phase+N+G |
|||||||
Voltage Range |
440/460/480Vac ±10% |
||||||||
Frequency Range |
50/60H±10% |
||||||||
Output |
Rated Voltage |
440/460/480Vac |
|||||||
Voltage Regulation |
±1% for balance load; ±3% for unbalance load |
||||||||
Rated Frequency |
50/60Hz |
||||||||
Frequency Precision |
50/60Hz±0.05%(Battery mode) |
||||||||
Outout PF |
0.9 |
||||||||
THDu |
<2% (linear load); <4% (non-linear load) |
<1% (linear load); <3% (non-linear load) |
|||||||
Crest Factor |
3:1 |
||||||||
Dynamic Voltage Transient |
<5% (from 0 to 100% load) |
||||||||
Transient Recovery Time |
<10ms (±5%) |
||||||||
Inverter Overload |
125% load for 10 mins; 150% load for 1min |
100%, continue; 125% load for 10 mins; 150% load for 1min |
|||||||
Battery |
Voltage |
360Vdc |
480Vdc, default (456Vdc, 504Vdc, settable) |
||||||
Battery Type |
Sealed maintenance-free lead-acid battery |
||||||||
Charging Voltage |
Float charging: 405Vdc; boost charging: 435Vdc |
Float charging: 540Vdc; boost charging: 580Vdc |
|||||||
Charging Current |
1-50A, settable according to the battery capacity |
||||||||
System |
Efficiency |
91% |
94% |
||||||
Protection Function |
Output short circuit protection; current-limiting protection |
||||||||
Transfer Time |
Normal mode to battery mode, 0ms |
||||||||
Display |
LCD+LED+Keyboard |
||||||||
IP Class |
IP20 |
||||||||
Communication Interface |
RS232, RS485(optional), SNMP card (optional) |
||||||||
Temperature |
Operation: 0-40 ℃; storage: -25-55 ℃ |
||||||||
Relative Humidity |
0-95%, no-condensing |
||||||||
Altitude |
<1500. Within 1500 to 4000m, power capacity decreases by 1% per 100m increasing in altitude |
||||||||
Noise (1-meter away) |
65dB |
71dB |
72dB |
74dB |
|||||
Physical |
Weight (kg) |
1480 |
2000 |
2050 |
2100 |
2500 |
3000 |
3500 |
4100 |
Dimension (W*D*H)mm |
1200*1500*1800 |
1300*1800*1800 |
2615*855*1900 |
2865*950*1900 |
3800*950*1900 |
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.